Communication via standard industrial fieldbus.
Configure as 1Nm (0.75 ft-lb) or 2Nm (1.5 ft-lb).
Motor power and Control power are isolated (E-stop motor without interrupting communication).
Bus addressing via interface or optional mechanical switches.
Optional baud rate selector.
Unique field configuration of physical cable orientation (by rotating the cap, three distinct cable connecti... more...

Communication via standard industrial fieldbus or Industrial EtherNet.
Configure as 1Nm (0.75 ft-lb), 2Nm (1.5 ft-lb) or 5Nm (3.75 ft-lb).
Motor power and Control power are isolated (E-stop motor without interrupting communication).
Bus addressing via interface or mechanical switches.
Optional Jog Keys input for manual operation (fieldbus only).
Absolute measuring system means no referencing.... more...

Communication via standard industrial fieldbus or Industrial EtherNet.
Configure as 1Nm (0.75 ft-lb), 2Nm (0.75 ft-lb), or 5Nm (3.7 ft-lb).
Motor power and Control power are isolated (E-stop motor without interrupting communication).
Bus addressing via interface or optional mechanical switches.
Optional Jog Keys for manual operation.
Absolute measuring system means no referencing.

Communication via standard industrial fieldbus or Industrial EtherNet.
Configure as 10Nm (7.5 ft-lb) or 25Nm (18.7 ft-lb).
Motor power and Control power are isolated (E-stop motor without interrupting communication).
Bus addressing via interface or optional mechanical switches.
Optional Jog Keys for manual operation.
Absolute measuring system means no referencing.

Communication via standard industrial fieldbus or Industrial EtherNet.
Configure to from 1Nm (0.75 ft-lb), 2Nm (1.5 ft-lb), or 5Nm (3.7 ft-lb).
Motor power and Control power are isolated (E-stop motor without interrupting communication).
Bus addressing via interface or optional mechanical switches.
Optional Jog Keys for manual operation.
Optional Brake.
Absolute measuring system means no ref... more...

Communication via standard industrial fieldbus or Industrial EtherNet.
Configure as 1Nm (0.75 ft-lb), 2Nm (0.75 ft-lb), or 5Nm (3.7 ft-lb).
Motor power and Control power are isolated (E-stop motor without interrupting communication).
Bus addressing via interface or optional mechanical switches.
Optional Jog Keys for manual operation.
Optional Brake.
Absolute measuring system means no refere... more...

Communication via standard industrial fieldbus or Industrial EtherNet.
Configure as 10Nm (7.5 ft-lb) or 18Nm (13.5 ft-lb)
Motor power and Control power are isolated (E-stop motor without interrupting communication).
Bus addressing via interface or optional mechanical switches.
Optional Jog Keys for manual operation.
Optional Brake.
Absolute measuring system means no referencing.

Analog input actuates position control loop.
Configure as 0.75Nm (0.57 ft-lb), 1.5Nm (1.15 ft-lb), or 3.5Nm (2.5 ft-lb).
Motor power and Analog feedback are isolated (E-stop motor without interrupting monitoring).
Analog measuring system means no referencing.

Analog input actuates position control loop.
Configure as 1Nm (0.75 ft-lb), 2Nm (1.5 ft-lb), 4Nm (3.0 ft-lb), or 5Nm (3.7 ft-lb).
Motor power and Analog feedback are isolated (E-stop motor without interrupting monitoring).
Analog measuring system means no referencing.

Analog input actuates position control loop.
Configure as 1Nm (0.75 ft-lb), 5Nm (3.7 ft-lb), or 10Nm (7.5 ft-lb).
Motor power and Analog feedback are isolated (E-stop motor without interrupting monitoring).
Analog measuring system means no referencing.

Analog input actuates position control loop.
Configure as 1Nm (0.75 ft-lb), 5Nm (3.7 ft-lb), or 10Nm (7.5 ft-lb).
Motor power and Analog feedback are isolated (E-stop motor without interrupting monitoring).
Analog measuring system means no referencing.

Large range of motion
Communication via standard industrial fieldbus or Industrial EtherNet.
Torque 15Nm (11.5 ft-lb)
High holding torque, even under zero-current conditions 25Nm (18.5 ft-lb).
Bus addressing via interface or mechanical switch.
Optional Jog Keys for manual operation.
Optional bevel gear.
Absolute measuring system means no referencing.
Optional Power distribution and data ... more...

Reduces System costs more than 40%
Less cabling - Less costs
Reduces addresses in bus systems for PLC
Needs less space in the machine and switchbox
For the connection up to 8 Hiperdrive